On the Optimum Placement of Dissipators in a Steel Model Building Subjected to Shaking-Table Tests
Abstract
The following research presents the numerical and experimental results obtained on a reduced scale steel model of a medium-rise building structure dynamically protected with energy dissipaters. The steel-steel friction dissipates energy as the structure undergoes interstory drifts. A preliminary numerical analysis is performed to determine the best position of the friction dampers in the longitudinal frames. All the nodes of the numerical model have been assumed with the same bending stiffness. Shaking table tests have been performed, both in random vibration tests (to determine the natural periods and the dynamic characteristics of the model) and in earthquake simulation tests (to study the dynamic behaviour of the model with and without dampers). The results have been compared to those achieved during a previous experimental study based on the same model protected with only one friction damper for each longitudinal frame.
Autore Pugliese
Tutti gli autori
-
FOTI D
Titolo volume/Rivista
THE OPEN CONSTRUCTION & BUILDING TECHNOLOGY JOURNAL
Anno di pubblicazione
2014
ISSN
1874-8368
ISBN
Non Disponibile
Numero di citazioni Wos
Nessuna citazione
Ultimo Aggiornamento Citazioni
Non Disponibile
Numero di citazioni Scopus
1
Ultimo Aggiornamento Citazioni
2017-04-22 03:20:59
Settori ERC
Non Disponibile
Codici ASJC
Non Disponibile
Condividi questo sito sui social