Retrospective analysis: a validation procedure for the redesign of an environmental monitoring network
Abstract
Monitoring networks are essential tools for the effective management of vulnerable or limited environmental resources. Cost and logistics constraints often suggest to reduce the number of monitoring sites while minimizing the loss of information determined by these changes. The problem can be rigorously addressed through the optimization of one or more objective functions that rep- resent the managerial goals associated to the network. However, the use of objective functions is based on assumptions that in practical cases can be inaccurate. To overcome this problem, we have developed a retrospective analysis procedure that validates the degree of acceptability of the optimal reduced configuration at a local and global level. The procedure has been applied to a case study in Apulia, Italy, finding that the optimal reduced network was unable to recover the measured values of the monitored parameter of two discarded locations, making it unable to accomplish its monitoring goals.
Autore Pugliese
Tutti gli autori
-
E. Barca; D.E. Bruno; A. Lay-Ekuakille; S. Maggi; G. Passarella
Titolo volume/Rivista
Measurement
Anno di pubblicazione
2018
ISSN
0263-2241
ISBN
Non Disponibile
Numero di citazioni Wos
Nessuna citazione
Ultimo Aggiornamento Citazioni
Non Disponibile
Numero di citazioni Scopus
Non Disponibile
Ultimo Aggiornamento Citazioni
Non Disponibile
Settori ERC
Non Disponibile
Codici ASJC
Non Disponibile
Condividi questo sito sui social