Mechanical stability of the CMS strip tracker measured with a laser alignment system
Abstract
The CMS tracker consists of 206m(2) of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from -25 to + 25 degrees C. The mechanical stability of tracker components during physics operation was monitored with a few mu m resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011-2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30 mu m. In addition, temperature variations were found to cause displacements of tracker structures of about 2 mu m/degrees C, which largely revert to their initial positions when the temperature is restored to its original value.
Autore Pugliese
Tutti gli autori
-
POMPILI A.;CALABRIA C.;MINIELLO G.;SELVAGGI G.;ABBRESCIA M.;DE PALMA M.;RADOGNA R.;VENDITTI R.;MY S.;NUZZO S.V.
Titolo volume/Rivista
Non Disponibile
Anno di pubblicazione
2017
ISSN
1748-0221
ISBN
Non Disponibile
Numero di citazioni Wos
Nessuna citazione
Ultimo Aggiornamento Citazioni
Non Disponibile
Numero di citazioni Scopus
Non Disponibile
Ultimo Aggiornamento Citazioni
Non Disponibile
Settori ERC
Non Disponibile
Codici ASJC
Non Disponibile
Condividi questo sito sui social