Low respiratory rate plus minimally invasive extracorporeal CO2 removal decreases systemic and pulmonary inflammatory mediators in experimental Acute Respiratory Distress Syndrome
Abstract
Objective: The Acute Respiratory Distress Syndrome Network protocol recommends limiting tidal volume and plateau pressure; it also recommends increasing respiratory rate to prevent hypercapnia. We tested a strategy that combines the low tidal volume with lower respiratory rates and minimally invasive CO2 removal. Subjects: Ten lung-damaged pigs (instilled hydrochloride). Interventions: Two conditions randomly applied in a crossover fashion: the Acute Respiratory Distress Syndrome Network protocol and the Acute Respiratory Distress Syndrome Network protocol plus lower respiratory rate plus minimally invasive Co2 removal. A similar arterial Co2 partial pressure was targeted in the two conditions. Measurements and Main Results: Physiological parameters, computed tomography scans, plasma and bronchoalveolar lavage concentrations of interleukin-1[beta], interleukin-6, interleukin-8, interleukin-10, interleukin-18, and tumor necrosis factor-[alpha]. During the lower respiratory rate condition, respiratory rate was reduced from 30.5 +/- 3.8 to 14.2 +/- 3.5 (p < 0.01) breaths/min and minute ventilation from 10.4 +/- 1.6 to 4.9 +/- 1.7 L/min (p < 0.01). The extracorporeal device removed 38.9% +/- 6.1% (79.9 +/- 18.4 mL/min) of CO2 production. During the lower respiratory rate condition, interleukin-6, interleukin-8, and tumor necrosis factor-[alpha] concentrations were significantly lower in plasma; interleukin-6 and tumor necrosis factor-[alpha] concentrations were lower in bronchoalveolar lavage, whereas the concentrations of the other cytokines remained unchanged. Conclusion: The strategy of lower respiratory rate plus minimally invasive extracorporeal CO2 removal was feasible and safe and, as compared with the Acute Respiratory Distress Syndrome Network protocol, reduced the concentrations of some, but not all, of the tested cytokines without affecting respiratory mechanics, gas exchange, and hemodynamics.
Autore Pugliese
Tutti gli autori
-
CROVACE A.;BRUNO F.;LACITIGNOLA L.;TREROTOLI P.;GRASSO S.
Titolo volume/Rivista
Non Disponibile
Anno di pubblicazione
2014
ISSN
0090-3493
ISBN
Non Disponibile
Numero di citazioni Wos
22
Ultimo Aggiornamento Citazioni
Non Disponibile
Numero di citazioni Scopus
23
Ultimo Aggiornamento Citazioni
Non Disponibile
Settori ERC
Non Disponibile
Codici ASJC
Non Disponibile
Condividi questo sito sui social