Enlargement of the aortic annulus during aortic valve replacement: a review
Abstract
The main goal of aortic valve replacement (AVR) is to obtain relief from the fixed left ventricular (LV) obstruction by replacing the aortic valve with a prosthesis, either mechanical or biological, of adequate size. Most currently available prostheses provide satisfactory hemodynamic performance, but small-sized prostheses may be associated with high transvalvular gradients and suboptimal effective orifice area that result in prosthesis-patient mismatch (PPM), and thus are far from ideal for use in young, active patients. The avoidance of PPM is advisable as it has been repeatedly associated with increased mortality, decreased exercise tolerance and an impaired regression of LV hypertrophy after AVR for severe aortic stenosis. Enlargement of the aortic annulus (EAA) has proved to be a valuable method to prevent PPM in the presence of a diminutive aortic root. This review outlines the various techniques described for EAA, presenting technical details, long-term results and major procedure-related complications, and discussing the current role of EAA in patients requiring AVR.
Autore Pugliese
Tutti gli autori
-
MILANO A.D.
Titolo volume/Rivista
Non Disponibile
Anno di pubblicazione
2014
ISSN
0966-8519
ISBN
Non Disponibile
Numero di citazioni Wos
8
Ultimo Aggiornamento Citazioni
Non Disponibile
Numero di citazioni Scopus
9
Ultimo Aggiornamento Citazioni
Non Disponibile
Settori ERC
Non Disponibile
Codici ASJC
Non Disponibile
Condividi questo sito sui social