Cardiovascular effects of continuous positive airway pressure (CPAP) in dogs under anesthesiaassessed by Doppler echocardiography
Abstract
General anesthesia impairs respiratory functionby the development of atelectasis in association with alteredventilation at pulmonary bases1. Applying Continuous Positive Airways Pressure (CPAP) in spontaneously breathing patients reduce the work of breathing, increases functional residualcapacity and is often recommended to prevent orreduce alveolar collapse1. In human medicine it has been widely recognized that an increase in intra-thoracic pressure is associated with a decrease in cardiac outputbecause of the reduction of venous return2. Nevertheless, conflictingresults (increases, decreases, or no change) in CO have beenreported and it was studied that the effects of CPAP on cardiac function were influenced by increasing CPAP levels. Doppler echocardiography represents a way to investigate how cardiac parameters can be affected and can change during CPAP application. What about CPAP application and its cardiovascular consequences in dogs? Aim of the study The aim of this study is to investigate by Doppler echocardiographythe cardiovascular effects of a low level of CPAP(5 cm H2O) in dogs under anesthesia. Materials and Methods 20 dogs have been enrolled in the study and divided into two groups. Both groups underwent anesthesia with a standard protocol and in Group A (10 dogs) CPAP was administered (5 cmH2O). Group B (10 dogs) served as control group and did not receive CPAP. Cardiovascular parameters (heart rate, mean arterial pressure and echocardiographic indices) were registered before (T0) and 15 minutes after anesthesia induction (T1), during anesthesia with or without CPAP(T2) and during recovery (T3).All patients were anesthetizedwith acepromazine (20 µg/kg), morphine (0.3 mg/kg), propofol (4 mg/kg) and isoflurane (end-tidal concentration 1.3 %)in spontaneous ventilation. Standard echocardiography (Esaote ultrasound system MyLab30) was performed usinga 2.5 MHz transducer. The following parameters were calculated as indicators of cardiovascular function: ejection fraction (EF%), left and right cardiac index (CI), left ventricle end diastolic volume index (LV-EDVI ml/m2), ratio of isovolumetric contraction time to ejection time (IVCT/ET), ratio of early rapid filling peak to atrial peak filling of transatrioventricular inflow (E/A), time velocity integral of atrioventricular inflow (TVI), aortic max velocity (AoVmax) and pulmonary max velocity (P Vmax). Results and Conclusions On the whole no statistical differences have been revealed in cardiovascular parameters at T2 compared to T1 in both groups.Interestingly a significant difference was revealed in EF between CPAP group and control group at T2. Myocardial diastolic properties remained unchanged. The right cardiac index do not change.Results of this study suggest not only that application of low levels of CPAP during anesthesia of healthy dogs does not negatively affect cardiac function and hemodynamic parameters, but also that it could positivelyinfluence the global left ventricular systolic function. In conclusion the application of this level of CPAP during anesthesia in healthy dogs could be considered safe. References 1Russo et al, 2013. J. CLIN. ANESTH. 25, 314-320.2Huemer et al, 1994. CHEST 106, 67-73
Autore Pugliese
Tutti gli autori
-
PULPITO D.;STAFFIERI F.;PARADIES P.;SPAGNOLO P.
Titolo volume/Rivista
Non Disponibile
Anno di pubblicazione
2015
ISSN
Non Disponibile
ISBN
Non Disponibile
Numero di citazioni Wos
Nessuna citazione
Ultimo Aggiornamento Citazioni
Non Disponibile
Numero di citazioni Scopus
Non Disponibile
Ultimo Aggiornamento Citazioni
Non Disponibile
Settori ERC
Non Disponibile
Codici ASJC
Non Disponibile
Condividi questo sito sui social