Accuracy of bioimpedance vector analysis and brain natriuretic peptide in detection of peripheral edema in acute and chronic heart failure
Abstract
To evaluate the role of bioelectrical impedance vector analysis (BIVA) and brain natriuretic peptide (BNP) in detecting peripheral congestion in heart failure (HF). Background BIVA/BNP are biomarkers for congestion in acute (ADHF) and chronic HF. Methods 487 ADHF and 413 chronic HF patients underwent BIVA and BNP tests. Results BIVA was more accurate than BNP in detecting peripheral congestion both in ADHF (AUC 0.88 vs 0.57 respectively; p < 0.001) and chronic HF patients (AUC 0.89 vs 0.68, respectively; p < 0.001). In ADHF patients, the optimal BNP cut-off for discriminating presence or absence of edema was >870 pg/mL (PPV = 48% and NPV = 58%) whereas in chronic HF it was >216 pg/mL (PPV = 18% and NPV = 95%). The BIVA detected edema when the vector fell into the lower pole of 75th percentile tolerance ellipse (PPV = 84% and NPV = 78%) in ADHF, the lower pole of 50% (PPV = 68% and NPV = 95%) in chronic HF. Conclusions In HF patients, BIVA is an easy, fast technique to assess peripheral congestion, and is even more accurate than BNP.
Autore Pugliese
Tutti gli autori
-
CICCONE M.M.;IACOVIELLO M.;CALDAROLA P.;GUIDA P.;SCICCHITANO P.
Titolo volume/Rivista
Non Disponibile
Anno di pubblicazione
2016
ISSN
0147-9563
ISBN
Non Disponibile
Numero di citazioni Wos
Nessuna citazione
Ultimo Aggiornamento Citazioni
Non Disponibile
Numero di citazioni Scopus
Non Disponibile
Ultimo Aggiornamento Citazioni
Non Disponibile
Settori ERC
Non Disponibile
Codici ASJC
Non Disponibile
Condividi questo sito sui social