A single-surgeon randomized trial comparing sutures, N-butyl-2-cyanoacrylate and human fibrin glue for mesh fixation during primary inguinal hernia repair

Abstract

Background: We sought to determine the efficacy of sutures, human fibrin glue and N-butyl-2-cyanoacrylate for mesh fixation in patients undergoing the plug and mesh procedure for groin hernia. Methods: A total of 156 patients with 167 inguinal hernias (11 bilateral) underwent a plug and mesh procedure and were randomly assigned to received either sutures (n = 59 hernias), human fibrin glue (n = 52) or N-butyl-2-cyanoacrylate (n = 56) for mesh fixation. Results: The overall morbidity rate was 38.98% in the suture group, 9.62% in the fibrin glue group and 10.71% in the N-butyl-2-cyanoacrylate group (suture v. fibrin glue, p < 0.001; suture v. N-butyl-2-cyanoacrylate, p < 0.001). There was no significant difference in morbidity between the fibrin glue and N-butyl-2-cyanoacrylate groups. Overall, short-term morbidity was significantly higher in the suture group (27.12%) than in the fibrin glue (9.62%, p = 0.01) or N-butyl-2-cyanoacrylate (8.93%, p = 0.004) groups, but there was no significant difference between the fibrin glue and N-butyl-2cyanoacrylate groups. There was no significant difference between the groups in terms of mean postoperative stay (32.6 h in the suture group v. 30.8 h in the fibrin glue group v. 32.0 h in the N-butyl-2-cyanoacrylate group) or mean time to return to work (20.4 d in the suture group v. 20.3 d in the fibrin glue group v. 19.8 d in the N-butyl-2-cyanoacrylate group). Overall, long-term morbidity was significantly higher in the suture group (11.86%) than in the fibrin glue (0%, p = 0.001) or N-butyl-2cyanoacrylate (1.78%, p = 0.03) groups. There was no recurrence in any of the groups. Two cases (3.39%) of chronic groin pain were reported in patients in the suture group. A sensation of extraneous body was reported in 5 (8.47%) patients who received sutures and in 1 (1.78%) patient in the N-butyl-2-cyanoacrylate group; there were no reported cases in the fibrin glue group (suture v. fibrin glue, p = 0.01; suture v. N-butyl-2-cyanoacrylate, p = 0.03; fibrin glue v. N-butyl-2-cyanoacrylate, p = 0.30). Conclusion: The use of human fibrin glue or N-butyl-2-cyanoacrylate is better tolerated than sutures in tension-free inguinal open repair using the plug and mesh technique in terms of overall immediate results, and there is a better trend in the long-term data.


Tutti gli autori

  • PICCINNI G.;TESTINI M.

Titolo volume/Rivista

Non Disponibile


Anno di pubblicazione

2010

ISSN

0008-428X

ISBN

Non Disponibile


Numero di citazioni Wos

Nessuna citazione

Ultimo Aggiornamento Citazioni

Non Disponibile


Numero di citazioni Scopus

Non Disponibile

Ultimo Aggiornamento Citazioni

Non Disponibile


Settori ERC

Non Disponibile

Codici ASJC

Non Disponibile