Time domain reflectometry, ground penetrating radar and electrical resistivity tomography: A comparative analysis of alternative approaches for leak detection in underground pipes

Abstract

In this work, three different techniques, namely time domain reflectometry (TDR), ground penetrating radar (GPR) and electrical resistivity tomography (ERT) were experimentally tested for water leak detection in underground pipes. Each technique was employed in three experimental conditions (one laboratory or two field experiments), thus covering a limited but significant set of possible practical scenarios. Results show that each of these techniques may represent a useful alternative/addition to the others. Starting from considerations on the obtained experimental results, a thorough analysis on the advantages and drawbacks of the possible adoption of these techniques for leak detection in underground pipes is provided.


Autore Pugliese

Tutti gli autori

  • A. Cataldo , R. Persico , G. Leucci , E. De Benedetto , G. Cannazza , L. Matera , L. De Giorgi

Titolo volume/Rivista

NDT & E INTERNATIONAL


Anno di pubblicazione

2014

ISSN

0963-8695

ISBN

Non Disponibile


Numero di citazioni Wos

32

Ultimo Aggiornamento Citazioni

28/04/2018


Numero di citazioni Scopus

33

Ultimo Aggiornamento Citazioni

28/04/2018


Settori ERC

Non Disponibile

Codici ASJC

Non Disponibile