Masonry vaults made by calcareous stone under fire conditions

Abstract

The analysis of the resistance to fire of masonry vaults represents an open issue due to the lack of analytical and/or experimental investigations in the technical literature as well as to the absence of national and international standard treating the specific topic. However, the Italian building heritage is often characterized by vaulted structures that need to be analysed also from a fire resistance point of view. To this scope in the present work, a first approach to study the behaviour of masonry vaults under thermal actions is reported taking into account the effect of the main influencing parameters.


Tutti gli autori

  • Leone M. , Aiello M.A.

Titolo volume/Rivista

Non Disponibile


Anno di pubblicazione

2017