Extending Industrial Applicability of TDR Liquid Level Monitoring Through Flexible Probes
Abstract
In the present work, an alternative probe configuration to be used for time domain reflectometry (TDR)-based monitoring of liquid level inside tanks is presented. The proposed probe, which resorts to a bifilar transmission line configuration, is flexible and adaptable to the surface of the containers to be monitored. This feature, along with the other advantageous characteristics of TDR, makes this probe configuration particularly attractive for industrial applications. In this paper, to test the applicability of the method, two different scenarios are considered: monitoring of liquids contained in metallic tanks and non-invasive monitoring of liquids in non-metallic tanks. Results show that, in both cases, the proposed system has considerable potential for being easily and effectively employed in practical, industrial applications.
Autore Pugliese
Tutti gli autori
-
Cataldo A. , Cannazza G. , De Benedetto E. , Piuzzi E.
Titolo volume/Rivista
Non Disponibile
Anno di pubblicazione
2013
ISSN
Non Disponibile
ISBN
Non Disponibile
Numero di citazioni Wos
Nessuna citazione
Ultimo Aggiornamento Citazioni
Non Disponibile
Numero di citazioni Scopus
6
Ultimo Aggiornamento Citazioni
26/04/2018
Settori ERC
Non Disponibile
Codici ASJC
Non Disponibile
Condividi questo sito sui social