A method for the outdoor thermal characterisation of highconcentrator photovoltaic modules alternative to the IEC 62670-3 standard
Abstract
The IEC 62670-3 standard recommends the open-circuit voltage method to calculate the cell temperature inside high-concentrator photovoltaic (HCPV) modules. This method requires knowledge of the temperature coefficient of open-circuit voltage (b), and the same standard provides a procedure to get this parameter. In this paper, an alternative method for the thermal characterisation of HCPV modules is proposed. As an advantage, it allows obtaining both the b parameter and the internal thermal resistance (r) of the device from outdoor measurements. No internal sensor for measuring the cell temperature is required as in the case of the IEC 62670-3 standard. Knowing the r parameter allows a more accurate characterisation of the cell temperature. The proposed procedure is applied to a real HCPV module. An outdoor experimental campaign of two months in Jaen (Southern Spain) was carried out. The b value was underestimated in a 0.50% and the r value was overestimated in a 4.18%. When applying the estimated parameters for the prediction of the cell temperature, the open-circuit voltage method gave a root mean square error (RMSE) of 1.41 C, while the internal thermal resistance method gave a RMSE of 0.62 C.
Autore Pugliese
Tutti gli autori
-
P.M. Rodrigo , R.Velazquez , E.F. Fernandez , F.M. Almonacid , A. Lay-Ekuakille
Titolo volume/Rivista
ENERGY
Anno di pubblicazione
2018
ISSN
0360-5442
ISBN
Non Disponibile
Numero di citazioni Wos
Nessuna citazione
Ultimo Aggiornamento Citazioni
Non Disponibile
Numero di citazioni Scopus
Non Disponibile
0
Ultimo Aggiornamento Citazioni
24/04/2018
Settori ERC
Non Disponibile
Codici ASJC
Non Disponibile
Condividi questo sito sui social